CONFIGURING AND TESTING STAR-System™
4
6. If the downloading procedure has completed successfully (after a series of
messages about automatic tests have been displayed and several beeps have
been emitted), the following message appears:
DATALOGIC RF DEMO
Any Key to start
Or F4 to Set
Press F4 and set the following parameters:
Addr. : ID address for RF terminal in the range 0-1999
F.Sta. : ID address for the first STARGATE™ to send data to in the range
0-1999
L.Sta. : ID address for the last STARGATE™ to send data to in the range
0-1999
Act. Dev.: : Number of devices simultaneously active in the RF network (range
1-2000)
CAUTION
If the data is sent to one STARGATE™ only, the F.Sta. and L.Sta.
address must correspond to the address of the STARGATE™ that
is being used.