Datalogic Scanning DS2200 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Lecteurs de codes-barres Datalogic Scanning DS2200. Datalogic Scanning DS2200 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Reference Manual

DS2200Reference Manual

Page 2

POWER SUPPLY - This product is intended to be installed by Qualified Personnel only. - DS2200 All Models: This device is intended to be supplie

Page 3

GENERAL VIEW DS2200 16547 32 8 Figure A 12345678Barcode Image Input WindowLaser Beam Output WindowPower On LEDGood Read LEDExt Trig LEDTX Data L

Page 4

GUIDE TO INSTALLATION The following can be used as a checklist to verify all the necessary steps for complete installation of the DS2200 scanner.

Page 5 - CONTENTS

INTRODUCTION 1 1 INTRODUCTION 1.1 PRODUCT DESCRIPTION The DS2200 scanner is a cost effective barcode reader complete with decoder designed to sati

Page 6

DS2200 1 A security system allows the laser to activate only once the motor has reached the correct rotational speed; consequently, the laser beam is

Page 7 - REFERENCES

INTRODUCTION 1 The following models are therefore available: DS2200 - X X X X Optical Resolution 1 = Standard Resolution 2 = High Resolution Readi

Page 8 - SAFETY PRECAUTIONS

DS2200 2 2 INSTALLATION 2.1 PACKAGE CONTENTS Verify that the DS2200 reader and all the parts supplied with the equipment are present and intact whe

Page 9 - CLASS 3B LASER PRODUCT

INSTALLATION 2 2.2 MECHANICAL INSTALLATION DS2200 can be installed to operate in any position. There are three screw holes (M2.5 x 5) on the body of

Page 10 - WEEE COMPLIANCE

DS2200 2 2.2.1 Mounting DS2200 Using the DS2200 mounting bracket you can obtain the most suitable position for the reader as shown in the figure belo

Page 11 - GENERAL VIEW

INSTALLATION 2 2.3 ELECTRICAL CONNECTIONS The DS2200 cable is equipped with a 25-pin female D-sub connector for connection with the power supply and

Page 13 - 1 INTRODUCTION

DS2200 2 2.3.1 Power Supply The following pins of the DS2200 connector are used: 13/9251VSGNDCHASSISUSER INTERFACEGNDV+ (5 Vdc)DS2200 Figure 4 - Pow

Page 14 - 1.2 MODEL DESCRIPTION

INSTALLATION 2 The following figure shows an example of a multidrop configuration between a Multiplexer and DS2200 scanners. 120 Ohmmax. 1200 m.RTX48

Page 15 - DS2200 - X X X X

DS2200 2 7SGNDSGNDTXDRXAUX3RXDTXAUX2USER INTERFACEDS2200 Figure 7 - RS232 auxiliary interface connections 2.3.4 Inputs The inputs available on the

Page 16 - 2 INSTALLATION

INSTALLATION 2 2.3.5 Outputs Two general purpose outputs are available. These outputs can only be connected as open collector configurations. The fol

Page 17 - 2.2 MECHANICAL INSTALLATION

DS2200 2 The Pitch angle is represented by the value P in Figure 10. Position the reader in order to minimize the Pitch angle. PFigure 10 - Pitch An

Page 18 - 2.2.1 Mounting DS2200

INSTALLATION 2 2.5 TYPICAL LAYOUTS The following typical layouts refer to system hardware configurations. Dotted lines in the figures refer to option

Page 19 - 2.3 ELECTRICAL CONNECTIONS

DS2200 2 The Master scanner is also connected to the Host on the RS232 auxiliary serial interface. The External Trigger signal is unique to the syste

Page 20 - 2.3.1 Power Supply

INSTALLATION 2 2.5.3 Multiplexer Each scanner is connected to a Multiplexer (for example MX4000) with the RS485 half-duplex main interface. 123RS48

Page 21 - INSTALLATION

DS2200 3 3 READING FEATURES The number of scans performed on the code by the DS2200 and therefore the decoding capability is influenced by the follo

Page 22 - 2.3.4 Inputs

READING FEATURES 3 For example, the DS2200 (500 scans/sec.) for a 25 mm high code moving at 500 mm/s performs: [(25/500) * 500] - 2 = 23 effective sca

Page 23 - 2.4 POSITIONING

DS2200 REFERENCE MANUAL

Page 24 - Figure 12 - Tilt angle

DS2200 3 3.3 PERFORMANCE The DS2200 scanner is available in different versions according to the reading performance. Version Max Code Resolution S

Page 25 - 2.5.2 RS485 Master/Slave

READING FEATURES 3 3.4 READING DIAGRAMS The following diagrams show the reading distance for barcodes with different densities. DS2200-1XXX (Standar

Page 26

DS2200 3 DS2200-2XXX (High Resolution) 10212(in)01 53(in)2401020304050 6070 8090100110120130(mm)6050403020100102030405060(mm)0.10 mm(4 mils)0.12 mm(5

Page 27 - 2.5.3 Multiplexer

MAINTENANCE 4 4 MAINTENANCE 4.1 CLEANING Clean the windows periodically for continued correct operation of the reader. Dust, dirt, etc. on the win

Page 28 - 3 READING FEATURES

DS2200 5 5 TECHNICAL FEATURES DS2200-1XXX DS2200-2XXX ELECTRICAL FEATURES Power Maximum input voltage 5 Vdc ± 5% Power consumption max. 2 W S

Page 29 - 3.2 PICKET-FENCE MODE

TECHNICAL FEATURES 5 SOFTWARE FEATURES READABLE CODE SYMBOLOGIES • EAN/UPC (including Add-on 2 and Add-on 5) • Code 93 • 2/5 Interleaved • Code

Page 30 - 3.3.1 Raster

GLOSSARY Aperture Term used on the required CDRH warning labels to describe the laser exit window. Barcode A pattern of variable-width bars and sp

Page 31 - 3.4 READING DIAGRAMS

EEPROM Electrically Erasable Programmable Read-Only Memory. An on-board non-volatile memory chip. Full Duplex Simultaneous, two-way, independent tra

Page 32

Protocol A formal set of conventions governing the formatting and relative timing of message exchange between two communicating systems. Raster The

Page 33 - 4 MAINTENANCE

Symbol A combination of characters including start/stop and checksum characters, as required, that form a complete scannable barcode. Tilt Rotation

Page 34 - 5 TECHNICAL FEATURES

DATALOGIC S.p.A. Via Candini 2 40012 - Lippo di Calderara di Reno Bologna - Italy DS2200 Reference Manual Ed.: 4/2006 ALL

Page 35 - (Note 3)

INDEX A Accessories; 3 C Cleaning; 21 E Electrical Connections; 7 G General View; ix Glossary; 24 Guide to Installation; x I Inputs; 10 Installatio

Page 36 - GLOSSARY

DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy 05 dichiara che declares that the déclare que le bescheinigt, daß das

Page 37

CONTENTS REFERENCES ... v Conventions...

Page 38

4 MAINTENANCE ... 21 4.1 Cleaning...

Page 39

REFERENCES CONVENTIONS This manual uses the following conventions: “User” or “Operator” refers to anyone using a DS2100A. “Device” refers to the D

Page 40

SAFETY PRECAUTIONS LASER SAFETY The following information is provided to comply with the rules imposed by international authorities and refers to

Page 41

The warning label indicating exposure to laser light and the device classification is applied onto the body of the scanner (Figure A, 8): CAUTION-C

Commentaires sur ces manuels