The warning label indicating exposure to laser light and the device classification is
applied onto the body of the scanner (Figure A, 8):
CAUTION-CLASS 3B LASER LIGHT
WHEN OPEN AVOID EXPOSURE TO BEAM
This product conforms to the applicable
requirements of 21CFR1040 at the date o
f
manufacture.
DATALOGIC S.p.A. Via Candini, 2
40012 Calderara di Reno - Bologna - Italy
LASER LIGHT
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
MAX. OUTPUT RADIATION 1 mW
EMITTED WAVELENGTH 630~680 nm
TO EN 60825-1:2001
Warning and Device Class Label
For installation, use and maintenance it is not necessary to open the scanner.
The laser diode used in this device is classified as a Class 3B laser product according
to EN 60825-1 regulations and as a Class IIIb laser product according to CDRH
regulations. As it is not possible to apply a classification label on the laser diode used
in this device, the following label is reproduced here:
LASER LIGHT
AVOID EXPOSURE TO BEAM
CLASS 3B LASER PRODUCT
MAXIMUM OUTPUT RADIATION 7 mW
EMITTED WAVE LENGTH
630
680 nm
TO EN 60825-1 (2001)
Laser Diode Class Label
Any violation of the optic parts in particular can cause radiation up to the maximum
level of the laser diode (7mW at 630680 nm).