9-pin C-Box 150 connector pinout in Normal mode
Pin Name Function
1 NC
2 RXA Auxiliary RS232
3 TXA Auxiliary RS232
4 NC
5 GND Ground
6 NC
7 RESERVED Device Dependent Signal
8 RESERVED Device Dependent Signal
9 NC
POSITION MODE
CFG: When the switch is in this position, the C-BOX 150 can be
configured. The communication with the scanner is interrupted and pins
2 and 3 are no longer dedicated to the scanner auxiliary interface but to
the C-BOX 150 configuration (see table below). The C-BOX 150 enters
configuration mode and waits to be configured through WinHost (see
WinHost Help On Line).
Once the C-BOX 150 configuration is completed, it is necessary to
return the switch in the Normal Operation position. At the end of the
reboot phase, the C-BOX 150 is ready to function with the new
configuration.
9-pin C-Box 150 connector pinout in Configuration mode
Pin Name Function
2 RX C-BOX 150 Configuration
3 TX C-BOX 150 Configuration
5 SGND Signal Ground
CAUTION
When the C-BOX 150 configuration is completed, remember to
return the Configuration switch in the Normal Operation position.